Home › Guides › Obtrusive light (GN01/21)

Obtrusive light: ILP GN01/21 environmental zones explained

A plain-English guide to the ILP Guidance Note for the Reduction of Obtrusive Light: environmental zones E0 to E4, curfews, and the limits councils check.

By Alkesh Gorsia CEng MIET, ILP registered · Updated November 2026

The Institution of Lighting Professionals' Guidance Note 01/21: The Reduction of Obtrusive Light is the document planning officers and environmental health officers most often refer to when judging external lighting. It sets limits for light pollution based on how dark the surrounding area is.

What is obtrusive light?

Obtrusive light is light that goes where it isn't wanted or needed. GN01/21 looks at three main effects:

  • Sky glow: the orange or white glow over towns and sites, caused by light going upwards directly or reflecting off surfaces.
  • Light intrusion: light spilling over the boundary, especially onto neighbours' windows.
  • Glare: bright fittings in someone's line of sight, from a neighbour's window or to drivers, cyclists and pedestrians.

The environmental zones

ZoneDescriptionTypical examples
E0ProtectedCore areas of dark sky reserves and parks
E1Natural, intrinsically darkNational Parks, National Landscapes, remote countryside
E2Rural, low district brightnessVillages, rural areas, darker edges of towns
E3Suburban, medium district brightnessSuburbs, small town centres
E4Urban, high district brightnessTown and city centres with lots of night-time activity

The darker the zone, the stricter the limits. A floodlit yard acceptable in a city may need a very different design in a village.

Get an instant fixed price using LuxQuotesAnswer a few questions and see your fixed price in about a minute.

Get my fixed price

What gets checked

For each zone, GN01/21 gives limits for:

  • Upward light ratio: how much of the light goes above the horizontal.
  • Light into windows: vertical illuminance at neighbours' windows, measured in lux, with a stricter limit after the curfew.
  • Luminous intensity of fittings in directions where they could cause glare.
  • Building luminance, for floodlit buildings.
  • Glare to road users, where lighting is near roads.

A lux contour plan and window calculations are the usual way to show compliance.

Practical ways to reduce obtrusive light

  • Flat-glass, fully shielded fittings installed level, not tilted up
  • Asymmetric floodlights that throw light forward without needing to be tilted
  • Rear shields and louvres facing neighbours
  • Lower mounting heights, or more fittings at lower output
  • Timers, motion sensors and dimming after curfew

Every LuxQuotes report identifies the right zone for your site and checks the scheme against it. Get an instant fixed price using LuxQuotes.

Frequently asked questions

What is the curfew in GN01/21?

The curfew is the time after which stricter limits apply. It is often 23:00, but the council can set a different time in a planning condition, and many conditions require lighting to be switched off or dimmed earlier.

How do I know which environmental zone my site is in?

The zone depends on the character of the area at night, not just the postcode. A lighting designer will assess it, and some councils publish their own zone maps or guidance. If the council has stated a zone, that takes priority.

Is obtrusive light the same as statutory nuisance?

Not quite. Statutory nuisance from artificial light is dealt with by environmental health under separate legislation. Meeting GN01/21 at the planning stage greatly reduces the risk of complaints later.

Get an instant fixed price using LuxQuotesAnswer a few questions and see your fixed price in about a minute.

Get my fixed price